There are two possible problems when considering using removable insulation blankets for outdoor applications:
• The potential for water to get underneath the blanket and stay, which could in turn lead to pipe corrosion under certain circumstances.
• The possibility of poor insulation performance when exposed to the elements.
Because insulation blankets, by nature, are not sealed, they are not impervious to water. Brett Herman, Firwin’s VP of sales and customer services, says the first question you should ask yourself when considering using insulation for an outdoor application is, “Can I afford any water getting under the blanket?” If the answer is no, then insulation blankets are not likely candidates for you application. However, if the problem isn’t a question of water getting under the blanket, but rather a fear of the water lingering, removable insulation remains a viable solution.
In many applications, high temperatures from typical engine exhaust cylinders (provided they are non-cyclical) will burn off excess water that remains under an insulation blanket—thus eliminating the risk of corrosion. In terms of ability to perform in outdoor conditions, insulation blankets’ standard outer layer (silicone impregnated fiberglass) can withstand temperatures as low was -67° F before cracking—and some even feature a UV resistant coating. When it comes to responding to water, some kinds of insulation are more water-resistant than others.
To accommodate outdoor applications, Firwin incorporates design modifications into blankets, such as extra flaps to reduce the amount of water that gets beneath a blanket. If corrosion is an issue, Firwin may also recommend consulting with an outside corrosion engineer.
For more information, continue reading about insulation blankets for outdoor applications here.
Thursday, December 8, 2011
Thursday, December 1, 2011
Appropriate Insulation for Marine Applications
Marine applications differ from land-based applications in three main areas: Firstly, a ship engine is typically used for prime power, so it is running all the time and generating a lot of continuous heat, unlike a back-up power generator. Secondly, and perhaps even more importantly, are the additional safety concerns that arise from being a sea-borne vessel—out on the water is not a place for heat-related issues. Thirdly, the engine room is often in tight quarters, increasing the likelihood that someone brushes up against a hot exhaust component.
For these reasons, Firwin typically recommends a thicker level of insulation than would suffice in standard non-marine power applications – usually 2-inch thick insulation blankets, as long as space allows. Extra care is also taken in designing the blankets to ensure that small gaps between components are covered. Firwin Hard Coat is also an excellent alternative to removable insulation blankets for marine applications, especially in cases where space constraints do not allow for thicker insulation.
For more information about insulation for marine applications, please contact us today.
Tuesday, November 29, 2011
Alternative Fastening Techniques for Insulation Blankets
Over the years, Firwin has developed more than a few ways of building fasteners for its removable insulation blankets, but its traditional modus operandi has always been with stainless steel lacing wire. “We find that stainless steel lacing wire works best,” says Paul Herman, Firwin’s president. “But for certain applications, where speedy installation is key, or where the client will be removing the [insulation] blankets frequently to do maintenance, we will recommend alternatives.”
So what are some of the alternatives? Thus far, Firwin has developed and produced insulation blankets that can be fastened by way of straps, snaps, springs, even Velcro. All of these options provide lighter, cheaper, and more accessible means of opening and closing insulation blankets.
A recent challenge: Firwin was tasked to develop a new spring system for one of its clients. But first there were a few slight problems that required solving. As Brett Herman, Firwin’s V.P. of Sales & Customer Service, sums it up, “We have made spring fasteners available to our customers in the past… However, we used to find that the spring fasteners available ‘off the shelf’ just did not provide the proper fit that insulation blankets require. We knew that if we were to provide spring fasteners as a legitimate option, we would have to design one ourselves.”
That’s just what Firwin did. Working with a local spring manufacturer, Firwin retrofitted their fasteners so that they would snap off with ease, all the while maintaining their sturdiness over time and at high temperatures. Insulation blankets fitted with these new and customized spring fasteners (as well as all other fastening alternatives) are currently available from Firwin upon request.
Monday, November 21, 2011
Insulation Outer Fabric: What are the Options?
An insulation blanket is composed of three main layers: An inner face, the insulation media itself, and the outer fabric. The inner face, known as the hot face, comes in direct contact with the hot component. Typically a stainless steel mesh, it holds the insulation in place. The outer fabric, known as the cold face, covers the insulation.
Outer fabric can be fluid-resistant or non-fluid resistant. Silicone or Teflon™ lamination endows the fabric with fluid-resistant properties, greater abrasion resistance, and the ability to withstand greater amounts of mechanical stress. Additionally, these types of fabrics are well suited to surviving the elements.
However, once temperatures reach above 500° F, the adhesives and coatings begin to break down, causing the material to lose integrity and become brittle. Some fabrics can continue to perform up to 600° F, at which point laminated fabrics maintain integrity while losing lamination. For extremely high-temperature applications, non-fluid resistant, woven, non-coated fabrics fare well. For applications that require fluid-resistance as well as high-temperature resistance, other materials must be considered.
Curious about what kind of outer fabric is right for your particular application? Read more to find out what other options are available.
Outer fabric can be fluid-resistant or non-fluid resistant. Silicone or Teflon™ lamination endows the fabric with fluid-resistant properties, greater abrasion resistance, and the ability to withstand greater amounts of mechanical stress. Additionally, these types of fabrics are well suited to surviving the elements.
However, once temperatures reach above 500° F, the adhesives and coatings begin to break down, causing the material to lose integrity and become brittle. Some fabrics can continue to perform up to 600° F, at which point laminated fabrics maintain integrity while losing lamination. For extremely high-temperature applications, non-fluid resistant, woven, non-coated fabrics fare well. For applications that require fluid-resistance as well as high-temperature resistance, other materials must be considered.
Curious about what kind of outer fabric is right for your particular application? Read more to find out what other options are available.
Monday, November 14, 2011
How to Install Firwin Removable Insulation Blankets
Last week, we discussed fastening techniques for insulation blankets. But what about proper installation? Combined with the right fastener, proper insulation installation is crucial in maximizing heat reduction. An improperly installed blanket can result in uncovered parts, heat leakage, or damage to the blanket—all of which can cost you time and money.
To help our customers get the most from our insulation, we’ve put together a basic guide to Firwin insulation blanket installation. This step-by-step guide, complete with pictures and diagrams, shows you exactly what do to and how to do it.
Firwin’s removable insulation blankets are available for many different applications, including manifolds, turbos, elbows, flanges, and flex joints, among others. Please contact Firwin directly if you require further instruction on installation for these or other components.
To help our customers get the most from our insulation, we’ve put together a basic guide to Firwin insulation blanket installation. This step-by-step guide, complete with pictures and diagrams, shows you exactly what do to and how to do it.
Firwin’s removable insulation blankets are available for many different applications, including manifolds, turbos, elbows, flanges, and flex joints, among others. Please contact Firwin directly if you require further instruction on installation for these or other components.
Monday, October 31, 2011
Energy Savings with Removable Valve Insulation
Getting the most out of your pipeline applications requires attention to heat—and sources of heat loss. The more heat you lose the higher the cost, so identifying key areas for insulation can go a long way towards increasing efficiency. Valves, flanges, expansion joints, and other irregular surfaces are common culprits of heat leakage, and maintenance often damages existing insulation. To circumvent these issues, many industrial professionals turn to removable insulation to maximize heat retention and increase pipe performance.
The U.S. Department of Energy recommends insulating any surface that reaches temperatures greater than 120° F, in order to protect personnel. The use of reusable insulation pads is pivotal in maintaining a safe environment: because the pads can be periodically removed for inspection and replaced as needed, they are an effective way to resolve current heat loss issues and prevent problems down the road.
Depending on valve size and operating temperatures, insulating valve covers can achieve impressive energy savings: the difference in heat loss between the un-insulated valve and the insulated valve operating at the same temperature. To get an idea of how much you can save, take a look at this helpful table from the U.S. Department of Energy.
Interested in removable valve insulation? Contact Firwin today to learn more about our hands-on service.
The U.S. Department of Energy recommends insulating any surface that reaches temperatures greater than 120° F, in order to protect personnel. The use of reusable insulation pads is pivotal in maintaining a safe environment: because the pads can be periodically removed for inspection and replaced as needed, they are an effective way to resolve current heat loss issues and prevent problems down the road.
Depending on valve size and operating temperatures, insulating valve covers can achieve impressive energy savings: the difference in heat loss between the un-insulated valve and the insulated valve operating at the same temperature. To get an idea of how much you can save, take a look at this helpful table from the U.S. Department of Energy.
Interested in removable valve insulation? Contact Firwin today to learn more about our hands-on service.
Monday, October 24, 2011
An Inside Look: Are Insulation Surface Temperatures Safe?
How hot does the outer surface of an insulation blanket get? When thinking about insulation temperatures, it’s important to remember that fabrics do not conduct heat; metals do. As a result, the relative temperature of a fabric surface can be higher, and still be safe to touch. However, it wasn’t until 1998 that a formal differentiation was made between metal and other surface types. For both, 140° F (60° C) had been the accepted standard temperature.
The UL220 Specification for Stationary Engine Generator Assemblies, issued in September of 1998, was the first standard to quantify acceptable temperatures. Based on this specification, fabric surfaces, such as insulation blankets, can reach temperatures up to 203° F (95° C), and still be safe enough for casual contact.
For more information about safe contact temperatures for insulation materials and more, please see our Firwin Insulation Insights FAQ.
The UL220 Specification for Stationary Engine Generator Assemblies, issued in September of 1998, was the first standard to quantify acceptable temperatures. Based on this specification, fabric surfaces, such as insulation blankets, can reach temperatures up to 203° F (95° C), and still be safe enough for casual contact.
For more information about safe contact temperatures for insulation materials and more, please see our Firwin Insulation Insights FAQ.